The EHG9608 Series is a highly reliable Gigabit Managed Ethernet Switch. Its IEC61850-3 compliance allows it to be core part in the IEC 61850 network in power substations and control centers. The series meets the IEC61850 applications and to support the transmission of GOOSE messages used for fast communication between IEDs.
The IEEE1588 Precision Time Protocol capabilities allow the deployment of EHG9608 Series in networks with stringent time Synchronization requirements. It can act as hw-assisted End-to-End transparent clock providing nanosecond-accurate correction-field packet-update and as a sw-assisted boundary clock.
The device equips up to 8x10/100/1000BASE-T(X) RJ-45 ports and up to 4 1000BASE-X SFP ports. With its high performance, it provides network redundancy self-recovery mechanisms is less than 20ms on full load that enables the user to build a reliable network through a redundant ring topology. ERPS/STP/MSTP/RSTP/MRP (Manager/ Client) and many other compatible rings are supported. With a Multifunctional web dashboard, its offers intelligent features such as Quality of service (QoS), Virtual LAN (VLAN), IGMP, IGMP Snooping, Port mirroring and security.
The EHG9608 Series is designed to be used in core power utilities. It provides dual redundant power inputs with Reverse Polarity Protection and two sets of relay that allow the user build up a stand-alone fault alarm system. Its wide operating temperature of -40 to 85°C and DIN-Rail mounting capacities make it suitable to be used in remote substations where harsh environment and reliability is an issue.
APPLICATION
EHG9608 is a product that specially fits with power station and substation application.
This product usually plays an important role at the bay level. With full gigabit ports, EHG9608 can help to transmit a bunch of data from process level to upper level. EHG9608 also supports IEEE 1588v2 HW-assisted End-to-End Transparent clock to deliver the precise time in power station or substation.
Environmental Limits | |
---|---|
Operating Temperature | -40°C to 85°C (-40°F to 185°F) /-40°C to 70°C (-40°F to 158°F) For UL |
Storage Temperature | -40°C~85°C (-40°F~185°F) |
Ambient Relative Humidity | 5%~95% RH, 55°C (Non-condensing) |
Physical Characteristics | |
---|---|
Housing | IP30 SPCC, Black housing |
Dimension (W x H x D) | 77 x 145 x 113 mm |
Weight | 1,000g (AC/HV versions) / 1,200g (other) |
Installation | DIN-Rail , Wall mount (optional kit) |
Power | |
---|---|
Rated Supply Voltage | 24-57 VDC 100-240 VAC for AC series 110-370 VDC for HV Series |
Input Voltage | 19.2-62.7 VDC 85-264 VAC for AC series 110-370 VDC for HV Series |
Input Current (System) | 0.63A @ 24 VDC 0.16A @ 100 VAC for AC series 0.12A @ 110 VDC for HV series |
Connector | 5-Pin 5.08mm Lockable Terminal Block |
Reverse Polarity Protection | Yes |
Interfaces | |
---|---|
RJ45 Ports | Up to 8x10/100/1000BASE-T(X) auto negotiation speed |
Fiber Optic Ports | Up to 4 1000BASE-X SFP slot |
LED Indicators | PWR1, PWR2, Alarm, Run, Ring, Ring Master, RJ-45 Link/Speed, SFP Link |
Console | RS232 (RJ45 connector) |
Relay Output | 2 x Relay outputs with current carrying capacity of 1A @ 24 VDC |
DIP Switches | Ring Control |
Reset Button | Yes |
Ethernet | |
---|---|
Standards | IEEE 802.3 for 10BASE-T IEEE 802.3u for 100BASE-T(X) IEEE 802.3ab for 1000BASE-T IEEE 802.3z for 1000BASE-X IEEE 802.3x for Flow Control/ Back pressure control IEEE 802.1d-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 8021x for Authentication |
Protocols | IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/v2c/ v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option 66/67/82, BootP, RARP, TFTP, NTP Server/Client, SNTP, SMTP, SMTP (Gmail), RMON, HTTP, HTTPS, Syslog, MRP (Manager/ Client), LLDP, IEEE 1588 PTP V1/V2, IEEE 1588 Hardware-Assisted End-to-End Transparent Clock and Software- assisted Boundary Clock, 802.1x, EAP, RADIUS, TACACS+, Mirror port, QoS, ACL, Serial Console, U-Ring, STP, RSTP, MSTP, Redundancy Compatible Ring, DHCP Snooping, ARP Spoof Prevention, Dynamic ARP Inspection, MLD, UDLD, IP Source Guard, sFlow |
Layer-3 Protocols | Routing: IPv4 Unicast static routing, RIP v1/v2, OSPFv2, Multicast: IGMPv1/v2/v3, DVMRP, PIM-DM, PIM-SM, PIM-SSM Routing Redundancy: VRRP (Virtual Router Redundancy Protocol) |
Automation Profiles | Modbus/TCP status registers |
SNMP MIB | MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011, RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415 |
Ethernet | |
---|---|
Priority Queues | 8 |
VLAN Table | 4096 |
MAC-Based VLAN | 512 |
VLAN ID Range | VID 1 to 4094 |
Trunk Group | 4 |
Static IGMP Groups | 128 |
Dynamic IGMP Groups | 256 |
MAC Table Size | 16K |
Packet Buffer Size | 1.5 MB |
Jumbo Frame | 9216 Byte |
Certification | |
---|---|
Warranty | 5 Years |
MTBF | 20 Years |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±8kV | 4 |
IEC 61000-4-2 | ESD | Air Discharge | ±15kV | 4 |
IEC 61000-4-3 | RS | 80-1000MHz | 20(V/m) | 3 |
IEC 61000-4-3 | RS | 1.0-3.0GHz | 10(V/m) | 3 |
IEC 61000-4-4 | EFT | AC Power Port | ±4.0kV @5.0kHz | 4 |
IEC 61000-4-4 | EFT | DC Power Port | ±4.0kV @5.0kHz | 4 |
IEC 61000-4-4 | EFT | Signal Port | ±4.0KV @5.0kHz | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±2.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | ±4.0KV | 4 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | Signal Port (L-2-E) | ±4.0KV | 4 |
IEC 61000-4-6 | CS | AC Power Port | 10V, 150kHz~80MHz, 80% AM | 3 |
IEC 61000-4-6 | CS | DC Power Port | 10V, 150kHz~80MHz, 80% AM | 3 |
IEC 61000-4-6 | CS | Signal Port | 10V, 150kHz~80MHz, 80% AM | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 100A/m continuous | 5 |
IEC 61000-4-8 | PFMF | Enclosure | 1000A/m for 1S | 5 |
IEC 61000-4-11 | DIP | AC Power Port | Drop 70% 3 times/S (1 Period) Drop 40% 3 times/1mS (50 Period) Drop 100% 3 times/50mS (5&50 Period) | - |
Certification | Standard |
---|---|
Safety | UL/CUL/IEC(CB) 61010-2-201 |
Industry Specific | IEC61850-3 (Including 6.10.3 Seismic test), IEEE 1613 |
EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4, |
RoHS 2 | Yes |
MODEL NAME | PART NUMBER | DESCRIPTION |
---|---|---|
Wall Mount Set | 70100000000056G | 45.4 x 22.8 x 1.5 mm Aluminum wall mount Kit with screw |
CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | RJ45 to DB9 Female Cross Over Console Cable, 90cm |
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply 88~264VAC / 124~370VDC input |
AXGD-5854-0513 | 522AXGD5854001G | SFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V, -40~85°C, DDMI |
AXGD-1354-0523 | 522AXGD1354001G | SFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V, -40~85°C, DDMI |
AXGD-1354-0533 | 522AXGD1354011G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V, -40~85°C,DDMI |
AXGD-3354-0593 | 522AXGD3354001G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V, -40~85°C,DDMI |
MODEL NAME | PART NUMBER | Description |
---|---|---|
EHG9608-2SFP | 1P1EHG96080001G | 2P*1000FX SFP;6P*1000TX RJ45; Power Input: DC |
EHG9608-2SFP-HV | 1P1EHG96080002G | 2P*1000FX SFP;6P*1000TX RJ45; Power Input: HV |
EHG9608-2SFP-AC | 1P1EHG96080003G | 2P*1000FX SFP;6P*1000TX RJ45; Power Input: AV |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v5.60 | Management Utility for Windows | 2021-06-01 | 23.65 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v0.1 | EHG9608-EHG9612 Hardware Installation Guide | 2021-06-01 | 8.53 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
EHG96XX MIB | 2022-12-05 | 20.21 KB |