Designed to be adaptive, with unprecedented throughput: Atop’s EHG7612 Series offers several different versions making it a very flexible product based on your specific needs for Layer-3 Switching. No matter the version, this device offers 4 x 1/10 Gigabit Ethernet SFP uplinks making it a cost-effective, reliable industrial solution where high-throughput and high-reliability is fundamental.
Layer-3 routing support IPv4 static routing, RIP v1/v2 and OSPFv2.
Designed for PoE, in wide temperature: EHG7616 supports up to 16 Gigabit ports in different configurations, either Copper, PoE or Fiber, any 8-port multiple configuration. Specifically designed for bringing power through Ethernet cable virtually anywhere, a maximum output Power over Ethernet of 240W over a maximum of 8 PoE/PoE+ ports is allowed (802.3af/at).
Rugged, Wide-Temperature, Well protected design: EHG7616 is EN61000-6-2, EN61000-6-4, IEC/EN/UL62368-1:2014 and FCC certified and is designed to withstand the harshest environments and the most demanding EMC environment. Its fanless design and EMC Level 3 protection guarantee reliable operations within -40 and +70°C, guaranteeing no packet is lost with all ports running full power and makes it suitable to be used for almost every application.
Powerul and versatile: With its high performance, it provides network redundant self-recovery mechanism is less than 20ms on full load that enables the user to build a reliable network through almost any redundant ring topology. It supports ITU-T G.8032 ERPS Ring, IEEE802.1D-2004 RSTP, STP, MSTP, MRP (Manager/ Client), iA-Ring, iA-Chain and many compatible rings protocols for network redundancy. With a Multifunctional web dashboard, its offers intelligent features such as QoS, VLAN, IGMP, Port mirroring and security.
Application-Specific: NEMA TS-2 Certification makes EHG7512/16/20 family the perfect choice for Smart City and Traffic Control applications.
Environmental Limits | Value |
---|---|
Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
Ambient Relative Humidity | 5% to 95%, 55°C (Non-condensing) |
Physical Characteristics | Value |
---|---|
Housing | IP30 SPCC Metal housing, ruggedized Heat-sink |
Dimension (W x H x D) | EHG7516-EHG7520 / EHG7616-EHG7620: 95 x 200 x 160 mm |
Weight | 2,500 g |
Installation | DIN-Rail, Wall mount (optional kit) |
Interfaces | Value |
---|---|
RJ45 Ports | Up to 16 10/100/1000BASE-T(X) auto negotiation speed |
Fiber Optics Ports | Up to 16 100/1000BASE-X SFP slot plus 4 1000BASE-X or 4 10G SFP slots |
LED Indicators | PWR1, PWR2, Alarm, Run, Ring, Ring Master, RJ-45 Link/Speed, SFP Link, PoE |
Console | RS232 (RJ45 connector) |
Relay Output | 2 relay outputs with current carrying capacity of 1A @ 24 VDC |
DIP Switches | Ring Control and Profinet Setting |
Button | Reset Button |
Power | Value |
---|---|
Input Voltage | 9-57 VDC for Non-PoE models 45-57 VDC for 802.3af mode 51-57 VDC for 802.3at mode |
Input Current (System) | Max. 2.2A @ 9 VDC (without PoE) Max. 3.3 A @ 45 VDC (Support up to 8 ports at 15.4 W per PoE port) Max. 5.2 A @ 51 VDC (Support up to 8 ports at 30 W per PoE port) |
Power Consumption (System) | Max. 19.8 W @ 9 VDC (without PoE) Max. 148.5 W @ 45 VDC (Support up to 8 ports at 15.4 W per PoE port) Max. 265.2 W @ 51 VDC (Support up to 8 ports at 30 W per PoE port) |
Connector | 5-Pin 5.08mm Lockable Terminal Block |
Reverse Polarity Protection | Yes |
Ethernet | Standard | - |
---|---|---|
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3ae For 10 Gigabit Ethernet Fiber IEEE 802.3x for Flow Control, back pressure flow control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP IEEE 802.3az for Energy Efficient Ethernet |
|
Protocols | IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/v2c/ v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option 66/67/82, BootP, RARP, TFTP, SMTP, SMTP (Gmail), RMON, HTTP, HTTPS, Syslog, MRP (Manager/ Client), LLDP,802.1x,EAP,RADIUS,TACACS+,Mirror port, QoS, ACL |
|
Layer-3 Protocols | Routing: IPv4 Unicast static routing, RIP v1/v2, OSPFv2, Multicast: IGMPv1/v2/v3, DVMRP, PIM-DM, PIM-SM, PIM-SSM Routing Redundancy: VRRP (Virtual Router Redundancy Protocol) |
|
Redundancy | ITU-T G.8032 ERPS Ring, STP, RSTP, MSTP, Compatible Ring/Chain, U-Ring | |
Time Synchronization | Network Synchronization | NTP Server/Client, SNTP |
Precision Network Synchronization | IEEE1588v1 OC/BC (Software) IEEE1588v2 E2E TC (Hardware) - ns acc. IEEE1588v2 OC/BC (Software) |
|
Automation Profiles | Modbus/TCP device status registers provided | |
SNMP MIB | MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011, RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674 |
Switch Properties | Value |
---|---|
Priority Queues | 8 |
VLAN Table | 4,096 |
MAC-Based VLAN | 512 |
VLAN ID Range | VID 1 to 4,094 |
Trunk Group | 4 |
Static IGMP Groups | 128 |
Dynamic IGMP Groups | 256 |
MAC Table Size | 16k |
Packet Buffer Size | 1.5 MB |
Jumbo Frame | 9216 Byte |
Certification | Standard |
---|---|
Shock | MIL-STD-810G Method 516.5 |
Drop | MIL-STD-810F Method 516.5 |
Vibration | MIL-STD-810F Method 514.5 C-1 & C-2 |
MTBF | 20 Years |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge Air Discharge | ±6KV ±8KV | 3 3 |
IEC 61000-4-3 | RS | 80-1000MHz 1.4-2.0GHz 2.0-2.7GHz | 10(V/m) 3(V/m) 10(V/m) | 3 3 3 |
IEC 61000-4-4 | EFT | AC Power Port DC Power Port Signal Port | ±2.0kV ±2.0kV ±1.0kV | 3 3 3 |
IEC 61000-4-5 | Surge | DC Power Port DC Power Port Signal Port | Line-to Line±1.0kV Line-to Earth±2.0kV Line-to Earth±2.0kV | 3 3 3 |
IEC 61000-4-6 | CS | 0.15-80MHz | 10V rms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 30 V/m | 4 |
IEC 61000-4-11 | DIP | AC Power Port | - | A |
Certification | Standard |
---|---|
Safety | UL62368-1, 2nd Ed., CSAC22.2 N. 62368-1-14,NZS62368.1:2018,EN62368-1:2014+A11:2017 |
Traffic Control | NEMA TS-2 |
EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4 |
RoHS 2 | Yes |
MODEL NAME | PART NUMBER | DESCRIPTION |
---|---|---|
WMK-450-Black | 70100000000052G | Aluminum wall mount kit |
CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | RJ45 to DB9 Female Cross Over Console Cable, 90cm |
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply 88~264VAC / 124~370VDC input |
SDR-240-48 | 50502401480001G | 240W/5A DIN-Rail 48~55VDC power supply 88~264VAC / 124~370VDC input |
SDR-480-48 | 50504801480001G | 480W/10A DINRail 48~55VDC power supply 88~264VAC /124~370VDC input |
AXFD-1314-0523 | 522AXFD1314001G | SFP Transceiver;155Mbps, Multi-mode;1310nm;2km;-40~85, DDMI |
AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver;155Mbps, Single-mode;1310nm;30km;-40~85, DDMI |
AXGD-5854-0513 | 522AXGD5854001G | SFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V, -40~85°C, DDMI |
AXGD-1354-0523 | 522AXGD1354001G | SFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V, -40~85°C, DDM |
AXGD-1354-0533 | 522AXGD1354011G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V, 40~85°C,DDMI |
AXGD-3354-0593 | 522AXGD3354001G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V, 40~85°C,DDMI |
AXXE-5886-05B3 | 522AXXE5886001G | SFP Transceiver, 10Gbps, SFP Transceiver,10Gbps Multi;850nm;300m;-40~85°C |
MODEL NAME | PART NUMBER | RJ45Port 1G | RJ45Port PoE 1G | SFP Port 1G | SFP Port 10G |
---|---|---|---|---|---|
EHG7616-410GSFP | 1P1EHG76160001G | 12 | 0 | 0 | 4 |
EHG7616-4PoE-410GSFP | 1P1EHG76160002G | 8 | 4 | 0 | 4 |
EHG7616-8PoE-410GSFP | 1P1EHG76160003G | 4 | 8 | 0 | 4 |
EHG7616-4SFP-410GSFP | 1P1EHG76160004G | 8 | 0 | 4 | 4 |
EHG7616-4PoE-4SFP-410GSFP | 1P1EHG76160005G | 4 | 4 | 4 | 4 |
EHG7616-8PoE-4SFP-410GSFP | 1P1EHG76160006G | 0 | 8 | 4 | 4 |
EHG7616-8SFP-410GSFP | 1P1EHG76160007G | 4 | 0 | 8 | 4 |
EHG7616-4PoE-8SFP-410GSFP | 1P1EHG76160008G | 0 | 4 | 8 | 4 |
EHG7616-12SFP-410GSFP | 1P1EHG76160009G | 0 | 0 | 12 | 4 |
EHG7616-8PoE-410GSFP (Marine) | 1P1EHG7516000AG | 4 | 8 | 0 | 4 |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
See in NMU | Network Management Utility | 2020-10-20 | 0 B | |
v5.20 | Management Utility for Windows | 2019-07-10 | 16.21 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v2.0 | EHG7512/EHG7516/EHG7520/EHG7612/EHG7616/EHG7620 Hardware Installation Guide | 2019-07-10 | 3.54 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
EHG76XX MIB | 2022-12-05 | 20.23 KB |