MB5916-CT Series

16-Port Rack-Mount Industrial Secure Modbus TCP/RTU/ASCII Gateway

  • Industrial EMC protection, Opt. Serial port Isolation, -20°C~70°C operation
  • 2 Fast-Ethernet ports, dual-subnet or redundancy
  • 8 sw-selectable RS-232/485/422 RJ45 serial ports, up to 921kbps
  • 24~48 VDC Power Input or 100~240 VAC Power input (EU or US version)
  • Bi-Directional Modbus TCP/RTU/ASCII conversion from Serial to Ethernet and viceversa, VirtualCOM support, advanced Modbus Options available
  • Supports SNMPv1/v2c/v3, Embedded security with IPsec VPN
  • Configuration via Web Browser / Serial Console / Telnet Console / Windows Utility / LCM Matrix
  • Integrated RSTP redundancy
  • Automatic mapping of all slaves’ data into memory, up to 64 connections
MB5916-CT Series
MB5916-CT Series
MB5916-CT Series
MB5916-CT Series

Diverse Hardware Infrastructure
Modbus Gateway supports the four most commonly used communication standards, RS-232/485/422, and Ethernet. The ease-of-use configuration utility provided with Modbus Gateway can quickly select the hardware interface, and easily switch to the existing communication infrastructure. You could set it up via Web Browser, Serial Console, Telnet Console, Windows Utility or through the LCM display in front of the device. Industrial EMC protection makes MB5916 ready for every mission.

Security and Redundancy
MB5916 embeds OpenVPN and IPsec VPN, that allows you to tunnel your data securely throught the internet and prevent unauthorized control of your Serial Devices by malicious people. The integrated Rapid Spanning Tree Protocol (RSTP), allows you to add a backup Ethernet link in the event the primary one fails.

Switching between Modbus Protocols
Modbus Gateway supports the standard Modbus protocol and is capable of converting any Modbus protocols between Modbus TCP, Modbus RTU, and Modbus ASCII for all supported hardware interfaces. All of this, in bidirectional mode: Ethernet and Serial ends can selected to be either master or slave.

Modbus ID Routing
Modbus Gateway supports various types of hardware communication interfaces, Modbus protocol conversion, and Modbus ID routing. Therefore the Modbus Gateway can integrate your existing and complex Modbus
hardware configuration into a simple network that can be easily managed.

Modbus Data Concentrator
The Modbus Data Concentrator performs pre-defined Modbus commands to read/write data from the slave devices via serial ports. It mirrors slave device data to its own memory. Therefore, requesting masters can receive response in a shorter period, achieving better overall efficiency.

Regular Modbus gateway

 

Modbus Concentrator

 

 

 

Network Interface
SpeedIEEE 802.3 10BaseT
IEEE 802.3u 100BaseT(X)
LAN ModeDual Subnets or Network Redundancy
Connector ports2x 10/100BASE-T(X) RJ-45
Serial Interface
ConnectorRJ45 RS-232/422/485 software selectable (-N models) or
RJ45 Isolated RS-422/485 software selectable (-SiS models)
Ports16
Baud Rate1,200 ~ 921,600 bps software selectable
Data Bits5, 6, 7, 8 software selectable
Stop Bits1, 2 software selectable
ParityNone, Odd, Even, Space, Mark
Flow ControlNone, Xon/Xoff, RTS/CTS (RS-232 only)
Isolation2.5 kV (Sis versions only)
Software
ProtocolsIPv4, ICMP, TCP, UDP, DHCP Client, SNMPv1,v2c,v3, HTTP, HTTPS, SMP/TLS,
Telnet, RFC2217, RSTP, Security through OpenVPN and IPsec (host-to-host or
host-to-side) with up to 37.9Mbps VPN throughput, and PPTP
ConfigurationAtop Management Utility, Web UI, Telnet, Serial Console, LCM Display
VirtualCOMWindows/Linux redirection software
Modbus Gateway Supported ModesEthernet: Modbus TCP Server/Client(or VCOM);
Serial: Modbus RTU/ASCII (master/slave)
Maximum number of Modbus clients/slavesModbus TCP: Maximum 16 clients;
Maximum 32 slave connections
Modbus concentratorOptional - please ask your ATOP Representative
Modbus redundant concentratorOptional - please ask your ATOP Representative
PowerValue
Rated Supply VoltageDC version: 24-48VDC; US-EU version: 100-240 VAC (EU or US Plug)
Input Voltage RangeDC version: 24-48VDC; US-EU version: 90-264 VAC (EU or US Plug)
Input CurrentDC version: 0.54 A @24VDC; US-EU version: 0.21A@100VAC
Power ConsumptionApproximately 21 W (Max)
ConnectorDC version: 5.08mm 3-pin Lockable Terminal Block
EU-US version: IEC 60320-1 C14 AC Power Inlet
Power RedundancyNo
Reverse Polarity ProtectionYes (DC version only)
Relay OutputYes (1)
Physical CharacteristicsValue
HousingIP30, metal housing
Dimension (W x H x D)436 mm x 43.5 mm x 200 mm
Weight3,000g (8-port version); 3,200 g (16-port version)
Installation19’’ Rack-Mount (Kit included)
Reset ButtonYes
Environmental Limits
Operating Temperature-20°C~70°C (-4°F~158°F)
Storage Temperature-40°C~85°C (-40°F~185°F)
Ambient Relative Humidity5%~95%, 55°C (Non-condensing)
CertificationStandard
SafetyEN60950-1:2006; EN62368-1
EMCFCC Part 15, Subpart B, Class A

EN55032, Class B, EN 61000-3-2, EN 61000-3-3, EN 55024
StandardItemTestValueLevel
IEC 61000-4-2ESDContact Discharge
Air Discharge
Contact Discharge
Air Discharge
±8kV (For AC Version)
±15kV (For AC Version)
±6kV (For DC Version)
±8kV (For DC Version)
4
4
3
3
IEC 61000-4-3RSRadiated (enclosure)10 V/m3
IEC 61000-4-4EFTAC Power Port
DC Power Port
Signal Port
±4.0KV
±4.0KV
±2.0KV
4
4
3
IEC 61000-4-5SurgeAC Power Port
AC Power Port
DC Power Port
DC Power Port
Signal Port
Line-to Line±2.0KV
Line-to Earth±4.0KV
Line-to Line±1.0KV
Line-to Earth±2.0KV
Line-to Earth±2.0KV
4
4
3
3
4
IEC 61000-4-6CSAC Power Port
DC Power Port
Signal Port
10 V rms
10 V rms
10 V rms
3
3
3
IEC 61000-4-8PFMFEnclosure1 A/m3
IEC 61000-4-11DIPAC Power Port30% Reduction (Voltage Dips),
25/30 Cycle
>95% Reduction(Voltage Dips),
0.5 period
100% Reduction (Voltage
Interruption) : 250/300 Cycle
-
CertificationStandard
Shock
Drop (Freefall) /Vibration
MIL-STD-810G Method 516.7
MIL-STD-810G Method 516.7 / MIL-STD-810G Method 514.7
RoHS IIYes
MTBF (MIL-HDBK-217F)MB5908-DC: 22.74 years; MB5916-US/EU: 13.95 years;
MB5908-SiS-DC: 19.00 years; MB5908-SiS-US/EU: 19.03 years
MB5916-SiS-DC: 13.38 years; MB5916-SiS-US/EU: 13.38 years
Warranty5 Years

DIMENSIONS & LAYOUT

MODEL NAME PART NUMBERDESCRIPTIONETHERNET PORTSSERIAL PORTS
MB5916-DC-CTContact
Headquarter
16-Port Modbus Concentrator, RJ45 serial, RS- 232/422/485,
24-48 VDC power input
2 (RJ45)16 (RJ45)
MB5916-EU-CT16-Port Modbus Concentrator, RJ45 serial, RS- 232/422/485,
100~240 VAC power input, EU Plug
2 (RJ45)16 (RJ45)
MB5916-US-CT16-Port Modbus Concentrator, RJ45 serial, RS- 232/422/485,
100~240 VAC power input, US Plug
2 (RJ45)16 (RJ45)
MB5916-SiS-DC-CT16-Port Modbus Concentrator, RJ45 serial, RS- 422/485,
2.5KV Isolation, 24-48 VDC power input
2 (RJ45)16 (RJ45)
MB5916-SiS-EU-CT16-Port Modbus Concentrator, RJ45 serial, RS-232, 2.5KV
isol., 100~240 VAC pwr, EU plug
2 (RJ45)16 (RJ45)
MB5916-SiS-US-CT16-Port Modbus Concentrator, RJ45 serial, RS-232, 2.5KV
isol., 100~240 VAC pwr, US plug
2 (RJ45)16 (RJ45)
MODEL NAME PART NUMBERDESCRIPTION
SDR-75-2450500752240001G75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input
AD17-24C (US-Y)50500151240002GY-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, US plug
AD17-24D (EU-Y)50500151240012GY-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, EU plug
GDC-12059906861G120mm copper woven grounding cable
CBL-RJ45(8P)-DB9(M)-9050891781GRJ45 to DB9 Male Cable, 90cm
CBL-RJ45(8P)-DB9(M)-20050891951GRJ45 to DB9 Male Cable, 200cm
CBL-RJ45(8P)-DB9(F)-9050891791GRJ45 to DB9 Female Cable, 90cm
CBL-RJ45(8P)-DB9(F)-90-C50891971GRJ45 to DB9 Female Cross Over Cable, 90cm
CBL-RJ45(8)-DB9(F)-200-C50891961GRJ45 to DB9 Female Cross Over Cable, 200cm
RMK-718-Black70100000000040GRack Mount Mounting-Kit, Black
Power Cable (US)50801041G6 feet Power Cable, US
Power Cable (EU)50801051G6 feet Power Cable, EU
Fuse50709441GFuse

Firmware

Version Name Time Size Download
v1.71 MB59xx CT Firmware 2023-08-21 16.3 MB

Datasheet

Version Name Time Size Download
v1.1 Datasheet EN 2023-08-25 432.96 KB
v1.2 Datasheet EN 2023-11-01 385.89 KB

Manual

Version Name Time Size Download
v1.5 MB59XX CT User Manual 2023-08-21 5.44 MB

Hardware Installation Guide

Version Name Time Size Download
v2.0 SE5908-SE5916-MB5908-MB5916-PG5908-PG5916 Hardware Installation Guide 2023-08-21 1.87 MB

Test reports

Version Name Time Size Download
EN 62368-1(AC models) 2023-08-21 3.91 MB
EN 62368-1(DC models) 2023-08-21 3.38 MB

I have read and agree to the Privacy Policy (art.13 and 14 of the GDPR - EU Regulation 2016/679).