The NSG3309 Series are compact 9-port NAT switches, equipped with 7 or 9 GbE RJ-45 ports and up to 2 Gbps SFP Fiber links. With configurable WAN/LAN ports and NAT features, accessibility for internal resources is fully controlled and protected. And combined with RSTP support, rings can be set up on both WAN and LAN side for full network redundancy.
Furthermore, this switch series’ IP30 metal enclosure, slim and flat shape and DIN rail mountable housing allows easy deployment in harsh environments. And being compliant with IEC62443-4-2 and IEC62443-4-1, they achieve both product security features and requirements for secure development life-cycle.
With these industrial-grade features, NSG3309 switches are ideal to be positioned as a proxy at the edge of networks.
Embedded SD Card Slot: Automatically backup configurations
periodically for use as the start-up configuration in the next booting. Recorded syslog can be saved in the SD card as well.
Virtual LAN: Divide local networks with 802.1q tagging to enhance data security and network efficiency.
Integrated NAT: Network deployment made simple with full NAT modes including 1:1 NAT, Virtual NAT, IP Masquerade, and DMZ.
Access Control: MAC/IPv4-based ACL is supported for LAN control.
Multi-Admin: Multiple Admin accounts with read-&-write or read-only access.
IEC62443: Development based on IEC 62443-4-1 and compliant with IEC 62443-4-2 to meet industrial network security standards.
APPLICATION CASE
Flexibility with Configurable WAN/LAN
NSG3309 series’ RJ-45 GbE ports can be configured as LAN or WAN ports. With built-in NAT functions, an extra router is not required for access between interior and exterior networks.
1:1 NAT
Establish WAN to LAN communication initiating from either side. Each LAN device is allocated a dedicated IP address from the external network, without the need of extra configuration on a router/gateway, and regardless of protocols.
Virtual NAT
Virtual NAT combines 1:1 NAT and virtual routing mechanisms. With 1:1 NAT, each external IP will be mapped to a virtual IP, and with this virtual IP, a virtual route will be created for accessibility to the LAN servers.
IP Masquerade
NSG3309 Series can act as a network proxy, allowing access of different LAN servers via a single external IP address with different TCP/UDP ports.
DMZ
Isolate specific LAN servers in the DMZ network to allow access from the external network while keeping the internal network secured.
WAN & LAN Backup
The NSG3309 series are equipped with configurable WAN/LAN ports. For WAN backup, integrate switch into an RSTP ring with 2 WAN ports connecting to 2 different uplinks. As a result, the redundant uplink will take over when the main uplink router fails. Simultaneously, RSTP allows for redundant topology on the LAN side to ensure network continuity.
INTERFACE | VALUE |
---|---|
RJ45 Ports | 7 x 10/100/1000BASE-T(X) for NSG3309-2SFP; 9 x 10/100/1000BASE-T(X) for NSG3309 |
Fiber Optics Ports | 2 x Gb FX SFP slots for SFP models |
LED Indicators | 1 x P1 & P2, 1 x Alarm, 1 x SFP1 & SFP2, 1 x LAN Ports |
Relay Output | 1 x Relay Output (24V/1A) with current carrying capacity of 1A @ 24 VDC |
SD-Card Slot | 1 x on Din-Rail side |
Button | 1 x Factory Reset |
CAPACITY | VALUE |
---|---|
NAT Throughput | 100 Mbps |
Switching Capacity | 18 Gbps |
Switching Fabric | 13.39 Mpps |
Packet Buffer Size | 2 Mb |
MAC Table Size | 16K |
Jumbo Frame | 10 KB |
NETWORKING | STANDARD | - |
---|---|---|
Ethernet Standards | IEEE 802.3 for 10Base-T IEEE 802.3u for 100Base-T(X) IEEE 802.3ab for 1000BaseT IEEE 802.3z for 1000BaseX IEEE 802.3x for Flow Control, back pressure flow control IEEE 802.1d-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid STP IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.3az for Energy Efficient Ethernet IEEE 802.1AB for LLDP Auto MDI/MDI-X |
|
Redundancy | RSTP | |
IP Version | IPv4 |
NAT | |
---|---|
1:1 NAT | Y |
Virtual NAT | Y |
IP Masquerading | Y |
Port Forwarding | Y |
DMZ | Y |
VLAN | |
---|---|
Max. Number of VLAN | 4KB |
VLAN ID | 2 (Optional) |
VLAN Type | Management VLAN Port-Based VLAN 802.1q Tag-Based VLAN |
Security | |
---|---|
Access Control List | MAC, IPv4 |
Time Synchronization | |
---|---|
Network Time Sync. | NTP Server/Client, SNTP |
Management | |
---|---|
Web Interface | HTTP, HTTPS |
SNMP | SNMPv1/v2c/v3, SNMP Trap/Inform |
SNMP MIB | RFC1213, Ethernet-like MIB, IF MIB, LLDP MIB |
LLDP | Y |
Syslog | Y |
DHCP Support | DHCP Server (port-based), DHCP Client |
Backup/Restore | Configuration backup periodically to SD card |
Diagnostics Utilities | RMON History, Port Mirror |
Physical | |
---|---|
Housing | IP30 SPCC, Black |
Dimension (W x H x D) | 60 x 110 x 89.6 mm for NSG3309 Series 45.3 x 110 x 89.6 mm for NSG3308 Series |
Weight | 400g (0.88lb) |
Installation | DIN-Rail mount / Wall mount (optional kit) |
Operating Temperature | -40°C to +70°C (-40°F to +158°F) |
Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
Ambient Relative Humidity | 5% to 95% (Non-condensing test @ 55°C) |
Input Voltage | 12 - 48VDC-Dual input |
Input Current | Max. 1.0 A |
Connector | 1 x 7-Pin 5.08mm Lockable Terminal Blocks for Power Input |
Reverse Polarity Protection | Y |
CERTIFICATION | STANDARD |
---|---|
Safety | UL 61010-1/-2-201 IEC 61010-1, EN 61010-1 IEC 61010-2-201, EN IEC 61010-2-201 |
EMI | FCC: Part 15, Subpart B, Class A |
EMI | CE: EN 55032, EN 61000-6-4, EN 61000-3-2 / EN 61000-3-3 |
EMS | CE: EN 55035, EN 61000-6-2 |
RoHS | Y |
STANDARD | ITEM | TEST | VALUE | LEVEL | CRITERION |
---|---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±6KV | 3 | B |
IEC 61000-4-2 | ESD | Air Discharge | ±8KV | 3 | B |
IEC 61000-4-3 | RS | 80-1000MHz | 10(V/m) | 3 | A |
IEC 61000-4-3 | RS | 1.4-6.0GHz 3(V/m) | 3(V/m) | 2 | A |
IEC 61000-4-4 | EFT | DC Power Port | ±2.0KV | 3 | B |
IEC 61000-4-4 | EFT | Signal Port ±1.0KV | ±1.0KV | 3 | B |
IEC 61000-4-5 | Surge | DC Power Port | Line-to-Line ±1.0KV | 3 | B |
IEC 61000-4-5 | Surge | DC Power Port | Line-to-Earth ±2.0KV | 3 | B |
IEC 61000-4-5 | Surge | Signal Port | Line-to-Earth ±2.0KV | 3 | B |
IEC 61000-4-6 | CS | 0.15-80MHz | 10V rms | 3 | A |
IEC 61000-4-8 | PFMF | Enclosure | 30A/m | 4 | A |
Model Name | Part Number | RJ-45 (10/100/1000 BASE-T) | SFP (1000FX) | NAT Throughput | Input Power |
---|---|---|---|---|---|
NSG3309 | 1P1NSG33090001G | 9 | - | 100 Mbps | 12-48VDC Dual input |
NSG3309-2SFP | 1P1NSG33090002G | 7 | 2 | 100 Mbps | 12-48VDC Dual input |
Model Name | Part Number | Description |
---|---|---|
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply 88 to 264VAC/124 to 370VDC input |
AXGD-5854-0513 | 522AXGD5854001G | SFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V, -40 to +85°C, DDMI |
AXGD-1354-0523 | 522AXGD1354001G | SFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V, -40 to +85°C, DDMI |
AXGD-1354-0533 | 522AXGD1354011G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V, -40 to +85°C, DDMI |
AXGD-3354-0593 I | 522AXGD3354001G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V, -40 to +85°C, DDMI |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.25 | NSG3309 Firmware | 2024-11-15 | 14.41 MB | |
v1.14 | NSG3309 Firmware | 2022-10-21 | 14.09 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.5 | Datasheet EN | 2023-10-02 | 413.56 KB | |
v1.4 | Datasheet EN | 2023-06-21 | 411.94 KB | |
v1.3 | Datasheet EN | 2022-10-26 | 506.2 KB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v0.3 | NSG3309 User Manual | 2022-10-21 | 2.62 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v0.1 | NSG3309 Hardware Installation guide | 2022-10-21 | 648.8 KB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
NSG3309 STP | 2022-10-21 | 30.93 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
CB Test Report | 2022-10-21 | 17.54 MB | ||
CE Test Report | 2022-10-21 | 8.14 MB | ||
FCC Test Report | 2022-10-21 | 3.1 MB | ||
UL Test Report | 2022-10-21 | 20.87 MB |