Product Description
The PG5908 Series is a highly reliable and fault tolerant Industrial Protocol Gateway. Its powerful architecture provides seamless conversion between the different protocols Ethernet or Serial based. The serial devices communicating on different protocols could be integrated into the system and extend its reach over the gateway’s redundant Ethernet. This device is designed to work in most demanding industries such as power substations, power generation, oil and gas, farming and manufacturing.
The configuration carried out through a use friendly, Java- Based Windows Utility called eNode Designer. It allows configuring target platforms, set device properties and protocol data point mapping. To do so, a project file representing the system should be created. This will include devices and the protocol applications running on them. The configuration is completely dependent on the “eNode Module” which represents that device or application – but may include things such as changing the communication port settings and defining where data point information enters and leaves the eNode Designer system.
PG5908 Series embeds an additional layer of security, allowing the devices to be deployed in topologies that request data to flow through the Internet and preventing sensitive control and monitoring data to be readable from malicious activities. IPsec VPN encryption, configurable in both peer-to-peer and peer-to-side modes will make sure the data passing is encrypted through a strong 128, 192 or 256-bit AES encryption.
An additional highlight of ATOP protocol gateways is the ability to enable multiple protocols simultaneously. In contrast to conventional gateways, which require predefinition of a single master and slave protocol each, the Full-License model* allows users to transform multiple incoming protocols in our protocol base to others compatible with the output side, achieving powerful protocol conversion functions, flexible operations, and easier maintenance.
*Coming soon
Application
The protocol gateway’s embedded protocol stacks allow
- Seamless conversion
- Exception/error Management
- Unsolicited event management for the protocols requiring them (such as DNP3)
- High performance
- Low cost
The example shows how to Easily connect a Modbus Serial HMI, through ATOP’s Protocol Gateway to a DNP3.0 IED. The host HMI has the role of a Modbus Serial Master while the end-device to be accessed is a DNP3.0 Ethernet Server.
ATOP’s protocol Gateway acts towards the HMI seamlessly as a Modbus Serial Slave, answering the poll commands or the write commands required by the Host by its virtual Modbus ID. Meanwhile, it acts as a DNP3.0 Ethernet Client, with regard to the end-device whose DNP3.0 address is mapped to the virtual Modbus ID that the HMI is accessing.
Be careful! – all gateway functions listed in the datasheet refer to the “Gateway” role, and not which “host” or “slave” the gateway is connected to. In this example, the SKU shown is “MBSS-DNEC” (Modbus Serial Slave to DNP3.0 Ethernet Client)
Network Interface | |
---|---|
Compliance | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) |
LAN Mode | Dual Subnets or RSTP LAN Redundancy |
Ethernet Port | 2x RJ-45 |
Serial Interface | |
---|---|
Connector | RJ-45 |
Ports | 8 |
Mode | RS-232/422/485, software selectable |
Baud Rate | 1,200 ~ 921,600 bps |
Parity | None, Odd, Even |
Data Bits | 5, 6, 7, 8 |
Stop Bits | 1, 2 |
Software | |
---|---|
Protocols | IPv4, ARP, ICMP, TCP, UDP, DHCP Client, DNS Client, Telnet, HTTP, HTTPS, SMTP/TLS, SNMP v1/v2c/v3, Syslog, RSTP, OpenVPN or IPsec VPN (peer-to-peer or peer-to-side), with a maximum VPN throughput of 37.9Mbps(*), and PPTP |
Protocol specifications | Refer to datasheet |
Power | Value |
---|---|
Rated Supply Voltage | DC version: 24-48VDC; US-EU version: 100-240 VAC (EU or US Plug) |
Input Voltage Range | DC version: 24-48VDC; US-EU version: 90-264 VAC (EU or US Plug) |
Power Consumption | 0.54A @ 24 VDC 0.21A @ 100 VAC |
Connector | IEC 60320-1 C14 AC Power Inlet (AC models) 5.08mm 3-pin Lockable Terminal Block (DC models) |
Power Redundancy | No |
Reverse Polarity Protection | Yes (DC version only) |
Physical Characteristics | Value |
---|---|
Housing | IP30, metal housing |
Dimension (W x H x D) | 436 mm x 43.5 mm x 200 mm |
Weight | 3,000g (8-port version); 3,200 g (16-port version) |
Installation | 19’’ Rack-Mount (Kit included) |
Reset Button | Yes |
Environmental Limits | |
---|---|
Operating Temperature | -20°C~70°C (-4°F~158°F) |
Storage Temperature | -40°C~85°C (-40°F~185°F) |
Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
Certification | Standard |
---|---|
Safety | EN60950-1:2006; EN62368-1 |
EMC | FCC Part 15, Subpart B, Class A EN 55032, Class A EN 61000-3-2 EN 61000-3-3 EN 55024 |
RoHS 2 | Yes |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±8kV (For AC Version) | 4 |
IEC 61000-4-2 | ESD | Air Discharge | ±15kV (For AC Version) | 4 |
IEC 61000-4-2 | ESD | Contact Discharge | ±6kV (For DC Version) | 3 |
IEC 61000-4-2 | ESD | Air Discharge | ±8kV (For DC Version) | 3 |
IEC 61000-4-3 | RS | Radiated (enclosure) | 10 V/m | 3 |
IEC 61000-4-4 | EFT | AC Power Port | ±4.0kV | 4 |
IEC 61000-4-4 | EFT | DC Power Port | ±4.0kV | 4 |
IEC 61000-4-4 | EFT | Signal Port | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±2.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | ±4.0KV | 4 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | Signal Port (L-2-L) | ±2.0KV | 4 |
IEC 61000-4-6 | CS | AC Power Port | 10 V rms | 3 |
IEC 61000-4-6 | CS | DC Power Port | 10 V rms | 3 |
IEC 61000-4-6 | CS | Signal Port | 10 V rms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 1 A/m | 3 |
IEC 61000-4-11 | DIP | AC Power Port | 30% Reduction (Voltage Dips), 25/30 Cycle >95% Reduction (Voltage Dips), 0.5 period 100% Reduction (Voltage Inter- ruption): 250/300 Cycle | - |
Certification | Standard |
---|---|
Shock | IEC 60068-2-27 |
Drop | ISTA Test Procedure 2A |
Vibration | IEC 60068-2-64 |
Warranty | 5 Years |
MTBF | PG5908-SiS-DC: 19.00 years; PG5908-SiS-US/EU: 19.03 years PG5916-SiS-DC: 13.38 years; PG5916-SiS-US/EU: 13.38 years |
HARDWARE | |
---|---|
PG5908-DC | Ind. 8-Port Protocol Gateway,RS-232/422/485 Software Selectable, DC TB3 |
PG5908-US | Ind. 8 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, US Plug |
PG5908-EU | Ind. 8 Port Protocol Gateway, RS-232/422/485 Software Selectable, AC Inlet, EU Plug |
PG5908-SiS-DC | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, DC TB3 |
PG5908-SiS-US | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, US Plug |
PG5908-SiS-EU | Ind. 8 Port Protocol Gateway, RS-422/485 Software Selectable, 2.5kV isolation, AC Inlet, EU Plug |
Protocols | |
---|---|
01SS-03SM | IEC 60870-5-101 Serial Slave to IEC 60870-5-103 Serial Master |
01SS-04EC | IEC 60870-5-101 Serial Slave to IEC 60870-5-104 Ethernet Client |
01SS-50EC | IEC 60870-5-101 Serial Slave to IEC 61850 Client |
01SS-DNEC | IEC 60870-5-101 Serial Slave to DNP3 Ethernet Client |
01SS-DNSM | IEC 60870-5-101 Serial Slave to DNP3 Serial Master |
01SS-MBEC | IEC 60870-5-101 Serial Slave to Modbus Ethernet Client |
01SS-MBSM | IEC 60870-5-101 Serial Slave to Modbus Serial Master |
04ES-01SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-101 Serial Master |
04ES-03SM | IEC 60870-5-104 Ethernet Server to IEC 60870-5-103 Serial Master |
04ES-50EC | IEC 60870-5-104 Ethernet Server to IEC 61850 Ethernet Client |
04ES-DNEC | IEC 60870-5-104 Ethernet Server to DNP3 Ethernet Client |
04ES-DNSM | IEC 60870-5-104 Ethernet Server to DNP3 Serial Master |
04ES-MBEC | IEC 60870-5-104 Ethernet Server to Modbus Ethernet Client |
04ES-MBSM | IEC 60870-5-104 Ethernet Server to Modbus Serial Master |
50ES-01SM | IEC 61850 Ethernet Server to IEC 60870-5-101 Serial Master |
50ES-03SM | IEC 61850 Ethernet Server to IEC 60870-5-103 Serial Master |
50ES-04EC | IEC 61850 Ethernet Server to IEC 60870-5-104 Ethernet Client |
50ES-DNEC | IEC 61850 Ethernet Server to DNP3 Ethernet Client |
50ES-DNSM | IEC 61850 Ethernet Server to DNP3 Serial Master |
50ES-MBEC | IEC 61850 Ethernet Server to Modbus Ethernet Client |
50ES-MBSM | IEC 61850 Ethernet Server to Modbus Serial Master |
DNES-01SM | DNP3 Ethernet Server to IEC 60870-5-101 Serial Master |
DNES-03SM | DNP3 Ethernet Server to IEC 60870-5-103 Serial Master |
DNES-04EC | DNP3 Ethernet Server to IEC 60870-5-104 Ethernet Client |
DNES-50EC | DNP3 Ethernet Server to IEC 61850 Ethernet Client |
DNES-DNSM | DNP3 Ethernet Server to DNP3 Serial Master |
DNES-MBEC | DNP3 Ethernet Server to Modbus Ethernet Client |
DNES-MBSM | DNP3 Ethernet Server to Modbus Serial Master |
DNSS-01SM | DNP3 Serial Slave to IEC 60870-5-101 Serial Master |
DNSS-03SM | DNP3 Serial Slave to IEC 60870-5-103 Serial Master |
DNSS-04EC | DNP3 Serial Slave to IEC 60870-5-104 Ethernet Client |
DNSS-50EC | DNP3 Serial Slave to IEC 61850 Ethernet Client |
DNSS-DNEC | DNP3 Serial Slave to DNP3 Ethernet Client |
DNSS-MBEC | DNP3 Serial Slave to Modbus Ethernet Client |
DNSS-MBSM | DNP3 Serial Slave to Modbus Serial Master |
MBES-01SM | Modbus Ethernet Server to IEC 60870-5-101 Serial Master |
MBES-03SM | Modbus Ethernet Server to IEC 60870-5-103 Serial Master |
MBES-04EC | Modbus Ethernet Server to IEC 60870-5-104 Ethernet Client |
MBES-50EC | Modbus Ethernet Server to IEC 61850 Ethernet Client |
MBES-DNEC | Modbus Ethernet Server to DNP3 Ethernet Client |
MBES-DNSM | Modbus Ethernet Server to DNP3 Serial Master |
MBSS-01SM | Modbus Serial Slave to IEC 60870-5-101 Serial Master |
MBSS-03SM | Modbus Serial Slave to IEC 60870-5-103 Serial Master |
MBSS-04EC | Modbus Serial Slave to IEC 60870-5-104 Ethernet Client |
MBSS-50EC | Modbus Serial Slave to IEC 61850 Client |
MBSS-DNEC | Modbus Serial Slave to DNP3 Ethernet Client |
MBSS-DNSM | Modbus Serial Slave to DNP3 Serial MasterMBSS-MBEC |
FL* | Allows a model to run single or multiple protocol(s) in both front-end to SCADA and back-end to IED sides |
*Coming soon |
OPTIONAL ACCESSORIES | ||
---|---|---|
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
Power Adapter AD17-24C (US-Y) | 50500151240002G | Y-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, US plug |
Power Adapter AD17-24D (EU-Y) | 50500151240012G | Y-Type power adaptor,100-240VAC input, 0.6A @ 24VDC output, EU plug |
GDC-120 | 59906861G | 120mm copper woven grounding cable |
CBL-RJ45(8P)-DB9(M)-90 | 50891781G | RJ45 to DB9 Male Cable, 90cm |
CBL-RJ45(8P)-DB9(M)-200 | 50891951G | RJ45 to DB9 Male Cable, 200cm |
CBL-RJ45(8P)-DB9(F)-90 | 50891791G | RJ45 to DB9 Female Cable, 90cm |
CBL-RJ45(8P)-DB9(F)-90-C | 50891971G | RJ45 to DB9 Female Cross Over Cable, 90cm |
CBL-RJ45(8)-DB9(F)-200-C | 50891961G | RJ45 to DB9 Female Cross Over Cable, 200cm |
RMK-718-Black | 70100000000040G | Rack Mount Mounting-Kit, Black |
Power Cable (US) | 50801041G | 6 feet Power Cable, US |
Power Cable (EU) | 50801051G | 6 feet Power Cable, EU |
Fuse | 50709441G | Fuse |