Flexible and powerful
ATOP’s high-density RHG7528 layer2-managed rackmount switch provides the flexibility to meet all kinds of requirements. Customization is made easy with 8 different switch cores, differing in power supply and uplink ports, and 3 swappable modules of different port types.
Of these, PoE ports allow both power and data transmission to wherever the Ethernet cable can reach. With 3 modules of 8 ports each, RHG7528 supports up to 24 Gigabit PoE/PoE+ (IEEE 802.3af/at) ports, so has at maximum 720W total power budget.
Rugged and resilient
Designed to work in all kinds of harsh environments, RHG7528 is EN 60950-1:2006 certified, available in 4 types of power input, fanless, and provides EMC level-3 protection. Reliable operation is guaranteed in the wide-range temperature of -40°C to +75°C. Various supported ring protocols enable self-healing ability for your network. ITU-T G.8032 ERPS Ring can even recover the network within 25 ms on full load of 250 devices. User-friendly WUI allows simple setup of basic functions like VLAN, QoS, IGMP, as well as network diagnostics via Port Mirroring.
Proven quality
The RHG7528 Series is compliant with IEC 62443-4-1 and IEC 62443-4-2 standards, which means that its development process as well as product features achieve world-class industrial network security. In addition, ACL by IP/MAC and 802.1x port access control with RADIUS filters unauthorized hosts, helping to keep your network safe.
Furthermore, the RHG7528 Series is EN 50155-certified to ensure reliable performance under a wide range of power supply conditions, and complies with essential sections of EN 50121-4 for railway ground equipment.
Consult RHG7528 datasheet to learn more about configuration examples.
Environmental Limits | Value |
---|---|
Operating Temperature | -40°C to +75°C (-40°F to +167°F) |
Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
Ambient Relative Humidity | 5% to 95% (Non-condensing test @ 55°C) |
Physical Characteristics | |
---|---|
Housing | IP30 SPCC metal housing |
Dimension (W x H x D) | 440 x 44 x 340 mm (not including screws and rack-mount kit) |
Weight | 5Kg (not including module but module cover only) |
Installation | 1U Rack-mount, Rack-mount kit included |
Power | ||
---|---|---|
Rated Supply Voltage | Switch Core | DC version: redundant 48-57 VDC AC version: single 110-220 VAC Redundant AC version: dual 110-220 VAC Mixed AC/DC -Redundant: 1x 110-220VAC & 1x 48-57VDC |
PoE | 2x 48-57 VDC | |
Input Voltage | Switch Core | DC version: redundant 48-57 VDC AC version: single 110-220 VAC Redundant AC version: dual 110-220 VAC Mixed AC/DC -Redundant: 1x 110-220VAC & 1x 48-57VDC |
PoE | 2 x 48-57 VDC | |
Max. Input Current | CPU board AC/ redundant AC: 64 W@110 VAC (with input current 0.6 A) CPU board redundand DC : 32.7 W@48 VDC (with input current 0.68 A) Full load of 802.3af PoE: 370 W@45 VDC (with input current 8.4 A) Full load of 802.3at PoE+: 720 W@51 VDC (with input current 14.4 A) |
|
Connectors | 2x Lockable 5-pin terminal blocks for PoE power input (all models) 2x Lockable 3-pin terminal blocks for DC power input (DC models) 1-2x AC power input (1x for non-redundant/-MR models; 2x for -R model ) 1x Lockable 3-pin terminal blocks for DC power input (-MR model) |
|
Relay Output | 2 x Relay Output with current carrying capacity of 1A @ 24 VDC | |
Reverse Polarity Protection | Yes |
Ethernet | Standard | - |
---|---|---|
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3ae for 10 Gigabit Ethernet Fiber IEEE 802.3x for Flow Control with back pressure flow control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.3ad for Port Trunk with LACP IEEE 802.3az for Energy Efficient Ethernet |
|
Protocols | IPv4, IPv6, IGMPv1/v2/v3, IGMP snooping, GARP, GMRP, GVRP, SNMPv1/ v2c/v3, SNMP Trap, ICMP, Telnet, SSH, Client/IP-port-mapping, BootP, TFTP, SMTP, SMTP (Gmail), RMON, HTTP, HTTPS, Syslog, MRP (Manager/Client), LLDP, 802.1x, EAP, RADIUS,TACACS+, Mirror port, QoS, ACL, ITU-T G.8032 ERPS Ring, STP, RSTP, MSTP, Compatible Ring/Chain, U-Ring, NTP Server/Client, Serial Console, Modbus/TCP, IEEE 1588 PTP V1/V2, UDLD, Security, PoE, Trunk, LACP, MLD, 802.1Q VLAN, Port-Based VLAN,MAC-Based VLAN, IP-Subnet-Based VLAN, Protocol-Based VLAN, QinQ, 802.1x, ARP spoof Prevention, DHCP snooping, IP source Guard, Dynamic ARP Inspection, DHCP relay Agent |
|
Redundancy | ITU-T G.8032 ERPS Ring, STP, RSTP, MSTP, Compatible Ring/Chain, U-Ring | |
Time Synchronization | Network Synchronization | NTP Server/Client, SNTP |
Precision Network Synchronization | IEEE1588 PTP v1/v2 IEEE1588 Hardware-based end-to-end transparent clock |
|
Automation Profiles | Modbus/TCP status registers | |
SNMP MIB | MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011, RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674 |
Switch Properties | Value |
---|---|
Priority Queues | 8 |
VLAN Table | 4,096 |
MAC-Based VLAN | 512 |
VLAN ID Range | VID 1 to 4,094 |
Static IGMP Groups | 128 |
Dynamic IGMP Groups | 256 |
MAC Table Size | 16k |
Packet Buffer Size | 1.5 MB |
Jumbo Frame | 9 K (9216 Bytes) |
Switching Fabric Capacity | 56 Gbps (4SFP model) / 128 Gbps (410GSFP model) |
Maximum throughput | 41.67 Mpps (4SFP model) / 95.24 Mpps (410GSFP model) |
Certification | Standard |
---|---|
Shock | MIL-STD-810G Method 516.5 |
Freefall | MIL-STD-810F Method 516.5 |
Vibration | MIL-STD-810F Method 514.5 C-1 & C-2 |
Rail Traffic | EN50155 / EN50121-4 Certified |
MTBF | 12.20 Years |
Warranty | 5 Years |
RoHS | Yes |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±8kV | 4 |
IEC 61000-4-2 | ESD | Air Discharge | ±15kV | 4 |
IEC 61000-4-3 | RS | Enclosure Port | 10(V/m), 80-1000MHz | 3* |
IEC 61000-4-4 | EFT | AC Power Port | ±2.0kV | 3 |
IEC 61000-4-4 | EFT | DC Power Port | ±2.0KV | 3 |
IEC 61000-4-4 | EFT | Signal Port | ±2.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | Signal Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-6 | CS | 0.15-80MHz | 10 V rms | 3* |
IEC 61000-4-8 | PFMF | Enclosure | AC 50Hz 10A/m | 3 |
IEC 61000-4-11 | DIP | AC Power Port | - | - |
* EMC level 3 on CS/RS pass conditional to the use of Shielded Ethernet Cable |
Certification | Standard |
---|---|
Safety | UL 60950-1 2nd Ed. /CSA C22.2 No.60950-1-07 2nd Ed. / EN 60950-1 / UL 62368-1 / IEC 62368-1 |
EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4 |
Optional Accessories | ||
---|---|---|
MODEL NAME | PART NUMBER | DESCRIPTION |
AC power cable (US) | 50801341G | AC power cable (SS004-240) for US region |
AC power cable (EU plug) | 50801351G | AC power cable (SS004-241) for EU region |
SDR-240-48 | 50502401480001G | DIN-rail power supply; 48-55 VDC, 100-240 VAC; 240 W@48 VDC (w/ input current 5 A) |
SDR-480-48 | 50504801480001G | DIN-rail power supply; 48-55 VDC, 100-240 VAC; 480 W@48 VDC (w/ input current 10 A) |
AXFD-1314-0523 | 522AXFD1314001G | SFP Transceiver, 155Mbps, Multi-mode, 1310nm, 2km, -40°C to +85°C, DDMI |
AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver, 155Mbps, Single-mode,1310nm, 30km, -40°C to +85°C, DDMI |
AXGD-5854-0513 | 522AXGD5854001G | SFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V, -40°C to +85°C, DDMI |
AXGD-1354-0523 | 522AXGD1354001G | SFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V, -40°C to +85°C, DDMI |
AXGD-1354-0533 | 522AXGD1354011G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V, -40°C to +85°C, DDMI |
AXGD-3354-0593 | 522AXGD3354001G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V, -40°C to +85°C, DDMI |
AXXE-5886-05B3 | 522AXXE5886001G | SFP Transceiver, 10Gbps Multi, 850nm, 300m, -40°C to +85°C |
Module Ordering Information | ||
---|---|---|
MODEL NAME | PART NUMBER | Description |
RHG7X28-M1 | 1P1RHG7X28M101G | Module with 8x Gb PoE RJ-45 |
RHG7X28-M2 | 1P1RHG7X28M201G | Module with 8x Gb RJ-45 |
RHG7X28-M3 | 1P1RHG7X28M301G | Module with 8x Gb SFP Slots |
Core Switch Ordering Information | ||||||
---|---|---|---|---|---|---|
MODEL NAME | PART NUMBER | Description | ||||
1Gb Uplink SFP | 10Gb Uplink SFP | 110-220 VAC input | 48-57 VDC input | 48-57 VDC PoE input |
||
RHG7528-CPU-4SFP | 1P1RHG7528CPU1G | 4 | - | 1 | - | 2 |
RHG7528-CPU-4SFP-R | 1P1RHG7528CPU2G | 4 | - | 2 | - | 2 |
RHG7528-CPU-4SFP-DC | 1P1RHG7528CPU3G | 4 | - | - | 2 | 2 |
RHG7528-CPU-410GSFP | 1P1RHG7528CPU4G | - | 4 | 1 | - | 2 |
RHG7528-CPU-410GSFP-R | 1P1RHG7528CPU5G | - | 4 | 2 | - | 2 |
RHG7528-CPU-410GSFP-DC | 1P1RHG7528CPU6G | - | 4 | - | 2 | 2 |
RHG7528-CPU-4SFP-MR | 1P1RHG7528CPU7G | 4 | - | 1 | 1 | 2 |
RHG7528-CPU-410GSFP-MR | 1P1RHG7528CPU8G | - | 4 | 1 | 1 | 2 |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
See in NMU | Network Management Utility | 2020-10-20 | 0 B | |
v5.20 | Management Utility for Windows | 2016-10-28 | 16.21 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.0 | RHG7528-RHG7628 Hardware Installation guide | 2017-04-03 | 5.73 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
RHG7528 MIB | 2022-12-05 | 20.71 KB |