Flexible: ATOP's high-density RHG7628 Managed Rack-mount switch will provide you the flexibility your application needs. You will be able to choose among 8 different Layer-3 Routing Core versions (based on power supply and uplink port configurations) and five different 4/8-Port modules and customize your device in a very simple way.
Designed for PoE, in wide temperature: RHG7628 supports up to 24 Gigabit ports in any 8 or 4-port multiple configuration. Specifically designed for bringing power through Ethernet cable virtually anywhere, a maximum output Power over Ethernet of 720W over the 24 ports is allowed (PoE/PoE+ configuration - 802.3af/at).
Available in 3 power input variants, it is EN 60950-1:2006 certified and designed to handle the harshest environments. Its fanless design and EMC Level 3 protection guarantee operations within -40 and +75°C, with 24 PoE ports running full power and makes it suitable to be used for almost every application.
Powerul and versatile: RHG7628 supports IPv4 Static Routing, RIPv1/v2, OSPFv2, IGMP, IGMP Snooping, PIM Dense Mode and Sparse Mode, DVMRP and VRRP for Routing Redundancy. Then, it embeds all features of RHG7528 (layer-2 version), allowing (through ERPS) network self-recovery down to 20ms on full load. Almost any redundant ring topology is supported, such as ITU-T G.8032 RPS Ring, IEEE802.1D-2004 RSTP, STP, MSTP, MRP (Client), iA-Ring, iA-Chain and many compatible rings. Endless additional features are provided.
Automation and IoT ready: conforming with Profinet CC-B v2.33 makes RHG7628 the perfect candidate for being the backbone of your Industrial automation network.
The RHG7628 Series is fully EN50155-certified to ensure reliable performance under a variety of power supply conditions, such as voltage variations, power interruptions, and supply changeovers, and it complies with essential sections of EN50121-4 for ground equipment.
Secure: The first Industrial Managed Secure Switch! Protect your LAN from Eavesdropping and impesronation through 802.1AE MACsec. With no additional latency and 100% Gigabit Throughput guarantee, dedicated modules can provide you the internal ultimate security solution.
Environmental Limits | Value |
---|---|
Operating Temperature | -40°C to +75°C (-40°F to +167°F) |
Storage Temperature | -40°C to +85°C (-40°F to +185°F) |
Ambient Relative Humidity | 5% to 95% (Non-condensing test @ 55°C) |
Physical Characteristics | |
---|---|
Housing | IP30 SPCC metal housing |
Dimension (W x H x D) | 440 x 44 x 340 mm (not including screws and rack-mount kit) |
Weight | 5Kg (not including module but module cover only) |
Installation | 1U Rack-mount, Rack-mount kit included |
Power | ||
---|---|---|
Rated Supply Voltage | Switch Core | DC version: redundant 48-57 VDC AC version: single 110-220 VAC Redundant AC version: dual 110-220 VAC Mixed AC/DC -Redundant: 1x 110-220VAC & 1x 48-57VDC |
PoE | 2x 48-57 VDC | |
Input Voltage | Switch Core | DC version: redundant 48-57 VDC AC version: single 99-242 VAC Redundant AC version: dual 99-242 VAC Mixed AC/DC -Redundant: 1x 99-240VAC & 1x 48-57VDC |
PoE | 2x 48-57 VDC | |
Max. Input Current | CPU board AC/ redundant AC: 64 W@110 VAC (with input current 0.6 A) CPU board redundant DC : 32.7 W@48 VDC (with input current 0.68 A) Full load of 802.3af PoE: 370 W@45 VDC (with input current 8.4 A) Full load of 802.3at PoE+: 720 W@51 VDC (with input current 14.4 A) |
|
Connectors | 2x Lockable 5-pin terminal blocks for PoE power input (all models) 2x Lockable 3-pin terminal blocks for DC power input (DC models) 1-2x AC power input (1x for non-redundant/-MR models; 2x for -R model ) 1x Lockable 3-pin terminal blocks for DC power input (-MR model) |
|
Relay Output | 2 x Relay Output with current carrying capacity of 1A @ 24 VDC | |
Reverse Polarity Protection | Yes |
Ethernet | Standard | - |
---|---|---|
Standards | IEEE 802.3 for 10BaseT IEEE 802.3u for 100BaseT(X) IEEE 802.3ab for 1000BaseT(X) IEEE 802.3z for 1000BaseX IEEE 802.3ae For 10 Gigabit Ethernet Fiber IEEE 802.3x for Flow Control, back pressure flow control IEEE 802.1D-2004 for Spanning Tree Protocol IEEE 802.1w for Rapid Spanning Tree Protocol IEEE 802.1s for Multiple Spanning Tree Protocol IEEE 802.1Q for VLAN Tagging IEEE 802.1p for Class of Service IEEE 802.1X for Authentication IEEE 802.1ae for MAC security (MACsec) – on RHG7X28-M4 & RHG7X28-M5 IEEE 802.3ad for Port Trunk with LACP IEEE 802.3az for Energy Efficient Ethernet |
|
Protocols | IPv4, IPv6, IGMPv1/v2/v3, IGMP Snooping, GARP, GMRP, GVRP, SNMPv1/v2c/ v3, SNMP Inform, ICMP, Telnet, SSH, DHCP Server/Relay/Client, DHCP Option 66/67/82, BootP, RARP, TFTP, SMTP, SMTP (Gmail), RMON, HTTP, HTTPS, Syslog, MRP (Client),LLDP,802.1x,EAP,RADIUS,TACACS+,Mirror port, QoS, ACL |
|
Layer-3 Switching Protocols | Routing: IPv4 Unicast static routing, RIP v1/v2, OSPFv2, Multicast: IGMPv1/v2/v3, DVMRP, PIM-DM, PIM-SM, PIM-SSM Routing Redundancy: VRRP (Virtual Router Redundancy Protocol) |
|
Redundancy | ITU-T G.8032 ERPS Ring, STP, RSTP, MSTP, Compatible Ring/Chain, U-Ring | |
Time Synchronization | Network Synchronization | NTP Server/Client, SNTP |
Precision Network Synchronization | IEEE1588v1 OC/BC (Software) IEEE1588v2 TC (Hardware) - ns accuracy IEEE1588v2 OC/BC (Software) |
|
Automation Profiles | Profinet v2.33 CC-B certified, Modbus/TCP device status registers provided | |
SNMP MIB | MIB II, IF-MIB, SNMPv2 MIB, BRIDGE-MIB, RMON MIB Group 1,2,3,9, RFC RFC 1157, RFC 1213, RFC 1215, RFC 1493, RFC 1643, RFC 1757, RFC 2011, RFC 2012, RFC 2013, RFC 2233, RFC 2571, RFC 2742, RFC 2819, RFC 2863, RFC 3411, RFC 3412, RFC 3413, RFC 3414, RFC 3415, RFC 2674 |
|
Uplink Port | 4 x 1 Gigabit or 4 x 10 Gigabit SFP | |
Switching Module Slots | 3 |
Switch Properties | Value |
---|---|
Priority Queues | 8 |
VLAN Table | 4,096 |
MAC-Based VLAN | 512 |
VLAN ID Range | VID 1 to 4,094 |
Static IGMP Groups | 128 |
Dynamic IGMP Groups | 256 |
MAC Table Size | 16k |
Packet Buffer Size | 1.5 MB |
Jumbo Frame | 9 K (9216 Bytes) |
Switching Fabric Capacity | 56 Gbps (4SFP model) / 128 Gbps (410GSFP model) |
Maximum throughput | 41.67 Mpps (4SFP model) / 95.24 Mpps (410GSFP model) |
Certification | Standard |
---|---|
Shock | MIL-STD-810G Method 516.5 |
Freefall | MIL-STD-810F Method 516.5 |
Vibration | MIL-STD-810F Method 514.5 C-1 & C-2 |
Rail Traffic | EN50155 / EN50121-4 Certified |
MTBF | 12.20 years |
Warranty | 5 Years |
RoHS | Yes |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±8kV | 4 |
IEC 61000-4-2 | ESD | Air Discharge | ±15kV | 4 |
IEC 61000-4-3 | RS | 80-1000MHz | 10 V/m | 3 |
IEC 61000-4-4 | EFT | AC Power Port | ±2.0kV | 3 |
IEC 61000-4-4 | EFT | DC Power Port | ±2.0KV | 3 |
IEC 61000-4-4 | EFT | Signal Port | ±2.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | ±1.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-5 | Surge | Signal Port (L-2-E) | ±2.0KV | 3 |
IEC 61000-4-6 | CS | 0.15-80MHz | 10 V rms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | AC 50Hz 10A/m | 4 |
IEC 61000-4-11 | DIP | AC Power Port | - | - |
* EMC level 3 on CS/RS pass conditional to the use of Shielded Ethernet Cable |
Certification | Standard |
---|---|
Safety | UL 60950-1 2nd Ed. /CSA C22.2 No.60950-1-07 2nd Ed. / EN 60950-1 / UL 62368-1 / IEC 62368-1 |
EMC | FCC Part 15, Subpart B, Class A EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3, EN 61000-6-2, EN 61000-6-4, |
Optional Accessories | ||
---|---|---|
MODEL NAME | PART NUMBER | DESCRIPTION |
AC power cable (US) | 50801341G | AC power cable (SS004-240) for US region |
AC power cable (EU plug) | 50801351G | AC power cable (SS004-241) for EU region |
SDR-240-48 | 50502401480001G | DIN-rail power supply; 48-55 VDC, 100-240 VAC; 240 W@48 VDC (w/ input current 5 A) |
SDR-480-48 | 50504801480001G | DIN-rail power supply; 48-55 VDC, 100-240 VAC; 480 W@48 VDC (w/ input current 10 A) |
AXFD-1314-0523 | 522AXFD1314001G | SFP Transceiver, 155Mbps, Multi-mode, 1310nm, 2km, -40°C to +85°C, DDMI |
AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver, 155Mbps, Single-mode,1310nm, 30km, -40°C to +85°C, DDMI |
AXGD-5854-0513 | 522AXGD5854001G | SFP Transceiver, 1250Mbps, 850nm, Multi-mode, 550m, 3.3V, -40°C to +85°C, DDMI |
AXGD-1354-0523 | 522AXGD1354001G | SFP Transceiver, 1250Mbps, 1310nm, Multi-mode, 2km, 3.3V, -40°C to +85°C, DDMI |
AXGD-1354-0533 | 522AXGD1354011G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 10km, 3.3V, -40°C to +85°C, DDMI |
AXGD-3354-0593 | 522AXGD3354001G | SFP Transceiver, 1250Mbps, 1310nm, Single-mode, 40km, 3.3V, -40°C to +85°C, DDMI |
AXXE-5886-05B3 | 522AXXE5886001G | SFP Transceiver, 10Gbps Multi, 850nm, 300m, -40°C to +85°C |
MODEL NAME | PART NUMBER | Description |
---|---|---|
RHG7X28-M1 | 1P1RHG7X28M101G | Module with 8x Gb PoE RJ-45 |
RHG7X28-M2 | 1P1RHG7X28M201G | Module with 8x Gb RJ-45 |
RHG7X28-M3 | 1P1RHG7X28M301G | Module with 8x Gb SFP Slots |
RHG7X28-M4 | 1P1RHG7X28M401G | Module with 8x Gb MACsec RJ-45 |
RHG7X28-M5 | 1P1RHG7X28M501G | Module with 8x Gb MACsec SFP Slots |
MODEL NAME | PART NUMBER | DESCRIPTION | ||||
---|---|---|---|---|---|---|
1Gb Uplink SFP | 10Gb Uplink SFP | 110-220 VAC input | 48-57 VDC input | 48-57 VDC PoE input | ||
RHG7628-CPU-4SFP | 1P1RHG7628CPU1G | 4 | - | 1 | - | 2 |
RHG7628-CPU-4SFP-R | 1P1RHG7628CPU2G | 4 | - | 2 | - | 2 |
RHG7628-CPU-4SFP-DC | 1P1RHG7628CPU3G | 4 | - | - | 2 | 2 |
RHG7628-CPU-410GSFP | 1P1RHG7628CPU4G | - | 4 | 1 | - | 2 |
RHG7628-CPU-410GSFP-R | 1P1RHG7628CPU5G | - | 4 | 2 | - | 2 |
RHG7628-CPU-410GSFP-DC | 1P1RHG7628CPU6G | - | 4 | - | 2 | 2 |
RHG7628-CPU-4SFP-MR | 1P1RHG7628CPU7G | 4 | - | 1 | 1 | 2 |
RHG7628-CPU-410GSFP-MR | 1P1RHG7628CPU8G | - | 4 | 1 | 1 | 2 |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
See in NMU | Network Management Utility | 2020-10-20 | 0 B | |
v5.20 | Management Utility for Windows | 2016-10-28 | 16.21 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v3.8 | Datasheet EN | 2024-10-08 | 952.46 KB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v2.4 | EHG76XX/ EHG96XX/ RHG76XX/ EMG86XX User Manual | 2023-05-29 | 10.46 MB | |
v0.2 | Managed Layer-3 Switch CLI User Manual | 2022-12-28 | 2.55 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v2.0 | RHG7528-RHG7628 Hardware Installation guide | 2024-12-20 | 5.88 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
RHG7628 MIB | 2022-12-05 | 20.23 KB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
RHG7X28 STP | 2024-12-20 | 82.7 MB |