Make Serial Devices Ready to the Network
The Industrial Serial Device Server SE5908A is a high-profile, high performance wide temperature gateway for Ethernet (TCP/IP) and serial signal communications; allowing almost any serial device to be connected to a new or existing Ethernet network. By encapsulating serial data and transporting it over Ethernet, it offers full-duplex and bi-directional data seamlessly between the serial port and the Ethernet network.
Advanced embedded security
SE5908A embeds IPsec VPN Encryption, that allows you to tunnel your data securely throught the internet and prevent unauthorized control of your Serial Devices by malicious people.
Easy to Use
Flexible configuration options enable this unit to be setup over Ethernet by Telnet, Web Browser, or our Windows Utility. Packed in a rugged metal housing for 19” rack mount with a redundant 24-48 VDC or High Voltage AC/DC power input, SE5908A is ideal for mission-critical applications in utilities and especially in power substations. Atop Virtual COM software provides a virtual environment for applications when accessing the device through TCP.
Rugged and flexible for advanced developments
SE5908A embeds high EMC protection, wide temperature operation, programming and installation flexibility in one device. The IEC61850-3 certified hardware makes it the most advanced Ethernet-to-Serial or Computing option, while the dual power supply provides additional redundancy in case of power failure. High-Voltage option makes the device suitable for High-Voltage AC or DC inputs (100~240 VAC or 100~370VDC) that are common in substation environments., without additional cabling and power supply.
SDK versions* allow you to make use of the powerful embedded TI ARM CPU, and develop your own applications on top of ATOP's reliable SDK transforming your deivce in a cost effective, performing industrial computing platform.
* More information available, please contact Atop representative or refer to SDK datasheet
Environmental Limits | |
---|---|
Operating Temperature | -40°C~80°C (-40°F~176°F) |
Storage Temperature | -40°C~85°C (-40°F~185°F) |
Ambient Relative Humidity | 5%~95%, 55°C (Non-condensing) |
Physical Characteristics | Value |
---|---|
Housing | IP30 SPCC housing |
Dimension (W x H x D) | 440.6 x 44 x 309 mm (1U Rack-mount) |
Weight | 4,000g |
Installation | 19’’ Rack-Mount (Kit included) |
Reset Button | Yes |
Power | Value |
---|---|
Rated Supply Voltage | Redundant 24-48 VDC or Redundant 100-240 VAC/ 100-370 VDC (HV Series) |
Input Voltage Range | Redundant 19.2-52.8 VDC or Redundant 85-264 VAC/ 100-370 VDC (HV Series) |
Input Current | 0.73 A @ 24 VDC 0.35 A @ 100 VAC 0.20 A @ 100 VDC |
Power Consumption | Approximately 20 W (Max) |
Connector | 10-Pin Terminal Block |
Power Redundancy | Yes |
Reverse Polarity Protection | Yes |
Software | |
---|---|
Protocols | IPv4, ICMP, TCP, UDP, DHCP Client, SNMPv1,v2c,v3, HTTP, HTTPS, Telnet, RFC2217, 802.1D-2004 RSTP, Security through OpenVPN Client/Server and IPsec (host-to-host or host-to-side) with up to 37.9Mbps VPN throughput, PPTP, and SMTP/TLS |
Configuration | Atop Management Utility, Web UI, Telnet, Serial Console |
VirtualCOM | Windows/Linux redirection software |
Link Modes - TCP Client | Single destination or VirtualCOM |
Link Modes - TCP Server | 4 Connections; VirtualCOM or reverse Telnet |
Link Modes - UDP | Up to 4 Ranges IP |
Serial Interface | |
---|---|
Connector | D-Sub9 (DB models, supporting only 5-pin RS-232 mode) or 5.08mm 5-Pin Terminal block (TB Models) |
Ports | 16 |
Mode | RS-232/422/485 Software selectable |
Serial Isolation | 3 kV (Sis versions only) |
Baud Rate | 1,200 ~ 921,600 bps software selectable |
Data Bits | 5, 6, 7, 8 software selectable |
Stop Bits | 1, 2 software selectable |
Flow Control | None, Xon/Xoff, RTS/CTS |
Network Interface | |
---|---|
Speed | IEEE 802.3 10BaseT IEEE 802.3u 100BaseT(X) - RJ45 version IEEE 802.3u 100Base-FX - SFP version |
Network mode | Independent IP address (6 ports) or Independent IP address (4 ports) + Unmanaged Switch (3 ports, including LAN4) |
Connector ports | RJ45 x 6 (RJ45 version) SFP x 6 (SFP version) |
Certification | Standard |
---|---|
Shock | MIL-STD-810F Method 516.5 |
Drop (Freefall) | MIL-STD-810F Method 516.5 |
Vibration | MIL-STD-810F Method 514.5 C1 & C2 |
RoHS | Yes |
MTBF | PG5900A: 16.60 years PG5916A-6SFP-Sis-HV: 9.18 years PG5916A-6SFP-Sis: 8.63 years |
Warranty | SE5916A-6SFP-Sis-HV: 9.18 years SE5916A-6SFP-Sis: 8.63 years PG5900A / PG5908A / PG5916A: 5 years |
Standard | Item | Test | Value | Level |
---|---|---|---|---|
IEC 61000-4-2 | ESD | Contact Discharge | ±8kV | 4 |
IEC 61000-4-2 | ESD | Air Discharge | ±15kV | 4 |
IEC 61000-4-3 | RS | Radiated (enclosure) | 20 V/m | 3 |
IEC 61000-4-4 | EFT | AC Power Port | ±4.0kV | 4 |
IEC 61000-4-4 | EFT | DC Power Port | ±4.0kV | 4 |
IEC 61000-4-4 | EFT | Signal Port | ±4.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-L) | Line-to Line±2.0KV | 4 |
IEC 61000-4-5 | Surge | AC Power Port (L-2-E) | Line-to Earth±4.0KV | 4 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-L) | Line-to Line±1.0KV | 3 |
IEC 61000-4-5 | Surge | DC Power Port (L-2-E) | Line-to Earth±2.0KV | 3 |
IEC 61000-4-5 | Surge | Signal Port (L-2-E) | Line-to Earth±4.0KV | 4 |
IEC 61000-4-6 | CS | AC Power Port | 10 V rms | 3 |
IEC 61000-4-6 | CS | DC Power Port | 10 V rms | 3 |
IEC 61000-4-6 | CS | Signal Port | 10 V rms | 3 |
IEC 61000-4-8 | PFMF | Enclosure | 100 A/m 1000 A/m (1sec.) | 5 6 |
IEC 61000-4-11 | DIP | AC Power Port | 30% reduction (Voltage Dips), 1 period 60% reduction (Voltage Dips), 50 period 100%, reduction (Voltage interruptions), 5 period 100% reduction (Voltage interruptions), 50 period | - |
Certification | Standard |
---|---|
Safety | EN61010-1, EN 61010-2-201 |
EMC | FCC Part 15, Subpart B, Class A, EN 55032, Class A, EN 61000-6-2, EN 61000-3-2, EN 61000- 3-3, EN 55024, EN 61000-6-4, IEC 61850-3 / IEEE 1613 |
MODEL NAME | PART NUMBER | DESCRIPTION |
---|---|---|
SDR-75-24 | 50500752240001G | 75W/3.2A DIN-Rail 24VDC power supply with 88~264VAC / 124~370VDC input |
GDC-120 | 59906861G | 120mm copper woven grounding cable |
ADP-DB9(F)-TB5 | 59906231G | Female DB9 to Female 3.81 TB5 Converter |
AXFD-1314-0523 | 522AXFD1314001G | SFP Transceiver;155Mbps, Multi-mode;1310nm;2km;-40~85, DDMI |
AXFD-1314-0553 | 522AXFD1314011G | SFP Transceiver;155Mbps, Single-mode;1310nm;30km;-40~85, DDMI |
MODEL NAME | PART NUMBER | DESCRIPTION | POWER INPUT | ETHERNET PORTS | SERIAL PORTS |
---|---|---|---|---|---|
SE5908A-6SFP | 1P1SE5908A0001G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, DB9 | 24~48 VDC | 6 (SFP) | 8 (DB9) |
SE5908A-6SFP-TB | 1P1SE5908A0002G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, TB5 | 6 (SFP) | 8 (TB5) | |
SE5908A-6SFP-Sis | 1P1SE5908A0003G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot,Isolated | 6 (SFP) | 8 (TB5) | |
SE5908A-6SFP-HV | 1P1SE5908A0004G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, DB9 | 100/240 VAC or 100/370 VDC | 6 (SFP) | 8 (DB9) |
SE5908A-6SFP-TB-HV | 1P1SE5908A0005G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, TB5 | 6 (SFP) | 8 (TB5) | |
SE5908A-6SFP-Sis-HV | 1P1SE5908A0006G | Ind. 8 Port Serial Server, 100BASE-FX SFP slot, Isolated | 6 (SFP) | 8 (TB5) | |
SE5908A | 1P1SE5908A0007G | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 24~48 VDC | 6 (RJ45) | 8 (DB9) |
SE5908A-TB | 1P1SE5908A0008G | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 6 (RJ45) | 8 (TB5) | |
SE5908A-Sis | 1P1SE5908A0009G | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, Isolated | 6 (RJ45) | 8 (TB5) | |
SE5908A-HV | 1P1SE5908A000AG | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, DB9 | 100/240 VAC or 100/370 VDC | 6 (RJ45) | 8 (DB9) |
SE5908A-TB-HV | 1P1SE5908A000BG | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, TB5 | 6 (RJ45) | 8 (TB5) | |
SE5908A-Sis-HV | 1P1SE5908A000CG | Ind. 8 Port Serial Server, 10/100BASE-T(X) RJ45, Isolated | 6 (RJ45) | 8 (TB5) |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.0 | Linux_Driver_x64 | 2021-03-29 | 210.16 KB | |
v5.60 | Management Utility for Windows | 2021-01-18 | 23.65 MB | |
v5.20 | Management Utility for Windows | 2016-10-28 | 16.21 MB |
Version | Name | Time | Size | Download |
---|---|---|---|---|
v1.4 | SE5908A Hardware Installation Guide | 2024-01-30 | 3.37 MB | |