EHG3005

Unmanaged Gigabit Ethernet Switch, 5-Port Slim-Type, Plastic Housing

  • 5 x 10/100/1000 Base-T(X) RJ45
  • Support 10K Jumbo frames
  • Support 802.3az Energy Efficient Ethernet for power savings
  • Support 802.1Q/p QoS, prioritizing critical packets such as PROFINET packets
  • Redundant DC power input
  • Operation temperature from 0 °C to 60 °C
  • DIN-Rail mounting
  • Slim type, plastic housing
New
EHG3005
EHG3005
EHG3005
EHG3005

EHG3005 is a slim, entry-level unmanaged switch with 5 RJ-45 ports and strict QoS packet prioritization according to 802.1p.Designed for industrial and especially for hazardous locations, it fits into small spaces in cabinets or between walls, and complieswith CE, FCC and UL standards, while featuring polycarbonate housing for cost efficiency.

Redundant power inputs allow simultaneous connection to wide-range DC power sources, so in case one of the power inputs fail, theother live source automatically acts as a backup to provide power.

Environmental Limits 
Operating Temperature0°C to 60°C (32°F to 140°F)
Storage Temperature-20°C to 70°C (-4°F to 158°F)
Ambient Relative Humidity5 to 95%, 55°C (non-condensing)
Physical Characteristics 
HousingIP30 protection, Plastic, Black
Dimension (W x H x D)Slim type, 23mm x 94mm x 72mm
WeightTBD
InstallationDIN-Rail mounting
LED IndicatorsPWR1, PWR2, Alarm, ALM, LAN
Power 
Dual Input Voltage12 - 48 VDC
Input Current0.5 A max.
Power Consumption6 W max.
Reverse Polarity ProtectionPresent
ConnectionLockable 5-pin terminal blocks for power input
ETHERNET
ComplianceIEEE 802.3 for 10Base-T
IEEE 802.3u for 100Base-T(X)
IEEE 802.3ab for 1000Base-T
IEEE 802.3z for 1000Base-X
IEEE 802.3x for Flow Control, back pressure flow control
IEEE 802.1q/p for VLAN Tagging and Class of Service
IEEE 802.3az for Energy Efficient Ethernet
Auto MDI/MDI-XYes
Switch Properties 
Processing SchemeStore-and-Forward
MAC Table Size8k
Packet Buffer Size1 MB
Jumbo Frame10K Bytes
TestVersion ItemValueLevelCriterion
IEC 61000-4-22008 ESDContact Discharge
Air Discharge
±6KV
±8KV
3
3
B
B
IEC 61000-4-32010RS80-1000MHz10 (V/m)3A
IEC 61000-4-42012EFTDC Power Port
LAN Port
±2.0KV
±2.0KV
3
4
B
B
IEC 61000-4-52014SurgeDC Power Port
DC Power Port
LAN Port
Line-to Line±0.5KV
Line-to Earth±0.5KV
Line-to Earth±2.0KV
3
3
3
B
B
B
IEC 61000-4-62013CS0.15-80MHz10 Vrms3A
IEC 61000-4-82009PFMFEnclosureAC 50Hz 30A/m4A
Noise ImmunitySimulator noise 500 Vp-p, noise width: 1 μs by noise simulator of 25 to 60 Hz in noise frequency (TBD)
RoHSYES
MTBF20 years (TBD)
Warranty5 Years
Regulatory Approvals 
SafetyUL/IEC 62368-1
FCC(EMI)FCC Part 15, Subpart B, Class A
CE(EMI)EN 55032:2015/AC:2016
EN 61000-3-2: 2014, Class A
EN 61000-3-3: 2013
EN 61000-6-4: 2007 + A1: 2011
CE(EMS)EN 55024:2010 + A1: 2015
EN 61000-6-2:2005 + AC: 2005

Drawing

Layout
Flow
Optional Accessories  
Model namePart NumberDescription
SDR-75-2450500752240001G75W/3.2A DIN-Rail 24VDC power supply with universal 88~264VAC / 124~370VDC input
Ordering information    
Model namePart NumberEnclosureRJ45 ports
EHG30051P1EHG30050001GPlastic5

Datasheet

Version Name Time Size Download
v0.6 Datasheet EN 2024-09-20 210.27 KB
v0.3 Datasheet 2022-12-13 210.9 KB
v0.2 Datasheet 2021-10-15 255.72 KB
v0.4 Datasheet EN 2023-10-02 217.02 KB

Hardware Installation Guide

Version Name Time Size Download
v1.0 EXG3X05 HARDWARE INSTALLATION GUIDE 2021-01-14 5.08 MB

Test reports

Version Name Time Size Download
EHG3005 Declarations of Conformity 2023-03-20 283.19 KB
v1.0 EHG3005 UL IEC62368-1 Test report 2021-02-26 4.64 MB
v1.0 EHG3005 UL Mark Document Complier Applicant 2021-02-26 15.62 MB
v1.0 EHG3005 UL Authorization letter 2021-02-26 115.89 KB
v1.0 EHG3005 UL CB Test Certificate IEC 62368-1 2021-02-26 281.97 KB
v1.0 EHG3005 UL CB Test Certificate IEC 60950-1 2021-02-26 182.53 KB
v1.0 EHG3005 UL IEC60950-1 Test report 2021-02-26 6.53 MB
v1.0 EHG3005 CE_EN61000-6-4/6-2 test report 2021-01-14 3.28 MB
v1.0 EHG3005 CE_EN55032/24 test report 2021-01-14 3.45 MB
v1.0 EHG3005 FCC Compliance 2021-01-14 1.97 MB

I have read and agree to the Privacy Policy (art.13 and 14 of the GDPR - EU Regulation 2016/679).